<LOGO>
FM Transmitter Measurement Report
Created: 2024-04-08 22-48-48
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.40 MHz 4/5, 40 dBuV VIBRA fm
Pilot RDS Phase Difference
6.6 kHz 3.1 kHz -86 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
15 kHz 67 kHz 4857 0,1029
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
6,0 dBr 7,69 dBr 8,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VIBRA fm" F560 9 (Varied) 1 0 1 1 --:--
RT
"PHARRELL WILLIAMS &MILEY CYRUS - Doctor (Work It Out) "
AF EON
90.3, 93.4, 101.7, 102.0, 102.1 MHz -
FM Scope Station: 93.40 MHz, signal: 4/5 (40 dBuV) Max at: 67 kHz MIN: 15 kHz % above 75 kHz: 0,1029 Acquired: 2024/04/08 22:47:44 Total samples: 4857 Equivalent time: 0:04:02 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 8,2 dBr MIN: 6,0 dBr AVE: 7,69 dBr % above 10,2 dBr: 0,0 Last value: 8,1 dBr (2024/04/08 22:47:44) Station: 93.40 MHz, signal: 4/5 (40 dBuV) 22:36 22:38 22:40 22:42 22:44 22:46 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality